Specifications:
Modem options: | Digi IX20 Cat 4 North America (LTE Bands B2, B4, B5, B12, B13, B14) or, Digi IX20 Cat 4 Global (EMEA/APAC LTE Bands B1, B2, B3, B4, B5, B7, B8, B12, B13, B18, B19, B20, B25, B26, B28, B39, B40, B41 |
Communication: | Static IP at Home Station PC and Dynamic IP at remote STS, e-mail alarm notifications |
Antennas: | 700/850 MHz BLADE SMA Male |
Data File Type: | .mdb (database), .xle, .lev or .csv (exported) |
Sampling Interval: | 10 seconds - 99 hours |
Reporting Interval: | 5 minutes - 1 week |
Schedule Programming: | Initial setup and remote updates done through Solinst Telemetry Software at Home Station |
Power Supply: | 12V, 12-30 AHr deep-cycle, rechargeable sealed lead-acid battery |
Optional Power Input: | 10V - 16V DC, 15W |
Battery Life Example: (4 dataloggers) | 1 year: based on hourly sampling and daily reporting |
Memory Capacity: (Between Reports) | 16 MB |
Operating Temperature: | -30ºC to 50ºC |
Optional Enclosure: | NEMA 4X (IP66: dust and water proof, can not be submerged) |
Compatible Dataloggers: | Levelogger 5 Series dataloggers, LevelVent 5, as well as previous versions of the LevelVent and Levelogger Edge Series dataloggers |
Number of Connected dataloggers: | 4 |
Barometric Compensation: | Using a connected Barologger, automatically performed in Solinst Telemetry Software or by user in external database |